Đại lý BALLUFF Việt Nam, BALLUFF Vietnam, BKS-S33M-00, BTL5-E17-M0075-B-NEX-S32, 37512140, 37512141, 37512192, MT-EOL 2K I 30 NL=1100, KARLSTEIN GERMANY, 2866776, PHOENIX CONTACT, SDS 2000, KTF 1 PT100 2L, S+S Regeltechnik GmbH
No
|
Name
|
Description
|
Part number
|
Manufacturer
|
1
|
Electrical switch
|
T y p e: 1 6 9 0
Contact: SPDT, bistable Contact material: rhodium Voltage: 230 V AC/DC Power switching: 40 W / 60 VA Enclosure rating: IP 67 (IEC 529) Connection: PVC-cable, length 3 m (standard) Housing material: Plastic (PBT black) |
Part-No. :641.6502.380.LI
|
Intra-automation
|
2
|
Micropulse linear transducer
|
- Type:BTL5-E17-M0075-B-NEX-S32
-Current output: E17 =20...4 mA, falling -Standard nominal stroke: 0075 -Housing: B M18×1.5 -Connection type: S32 with connector |
|
BALLUFF
|
3
|
Connector
|
- Type: BKS-S33M-00
- Electrical connection: + Cable diameter D :8mm + Contact shield: Shield ring + Number of pins: 8 + System; Can be fabricated - Electrical data: + Rated current (40 °C): 5.0 A - Environmental conditions: +Ambient temperature: -40…95 °C +Protection type IEC 60529: IP67 - Material: + Material contact carrier : PBT + Material contacts :Bronze + Material cover nut : Brass + Material grip: Die-cast zinc - Mechanical data: +Connection cross-section: 0.75 mm² +Type of wire mounting :Solder connections |
|
BALLUFF
|
10
|
Micropulse linear transducer
|
- Type:BTL5-E17-M0075-B-NEX-S32
-Current output: E17 =20...4 mA, falling -Standard nominal stroke: 0075 -Housing: B M18×1.5 -Connection type: S32 with connector |
|
BALLUFF
|
11
|
Connector
|
- Type: BKS-S33M-00
- Electrical connection: + Cable diameter D :8mm + Contact shield: Shield ring + Number of pins: 8 + System; Can be fabricated - Electrical data: + Rated current (40 °C): 5.0 A - Environmental conditions: +Ambient temperature: -40…95 °C +Protection type IEC 60529: IP67 - Material: + Material contact carrier : PBT + Material contacts :Bronze + Material cover nut : Brass + Material grip: Die-cast zinc - Mechanical data: +Connection cross-section: 0.75 mm² +Type of wire mounting :Solder connections |
|
BALLUFF
|
4
|
Thermocouple
|
- MODEL:37512140
- Type: MT- EOL 2K I 30 NL=3100 - Nicr-Ni dia 3 x 3000 38Z1-01955 - TEMP: 0..+10000C |
|
KARLSTEIN GERMANY
|
5
|
Thermocouple
|
- MODEL:37512141
- Type:MT- EOL 2K I 30 NL=2100 -TEMP: 0..+10000C - Nicr-Ni dia 3 x 2000 38Z1-01955 |
|
KARLSTEIN GERMANY
|
6
|
Thermocouple
|
- MODEL:37512192
- Type:MT-EOL 2K I 30 NL=3300 -TEMP: 0..+10000C - Nicr-Ni dia 3 x 3200 - Nicr-Ni dia 3 x 1000 |
|
KARLSTEIN GERMANY
|
7
|
Thermocouple
|
- Type:MT-EOL 2K I 30 NL=1100
-TEMP: 0..+1000 deg C |
|
KARLSTEIN GERMANY
|
8
|
Power supply
|
-Input data:
+ Nominal input voltage:100 V AC ... 240 V AC + AC input voltage range: 85 V AC ... 264 V AC + DC input voltage range: 90 V DC ... 350 V DC +Short-term input voltage:300 V AC + AC frequency range:45 Hz ... 65 Hz - Output data: + Nominal output voltage:24 V DC ±1% + Setting range of the output voltage:18 V DC ... 29.5 V DC (> 24 V constant capacity) +Output current: 20 A (-25°C ... 60°C, UOUT = 24 V DC) |
Order No.: 2866776
|
PHOENIX CONTACT
|
9
|
Condensate Drainage
|
Model: 20 FM
Voltage: 230Vac Pressure:0.8-16bar Connections Inlet:1x G 1/2 Connections outlet:1x G 1/4 |
|
BEKOMAT
|
12
|
Thermotronic 61 Electronic temperature sensor
|
- type: Thermotronic 61-00V004
- range of temperature display:: from -20 to +120 °C - range of alarm indication:0 to +99 °C - display: : three digit seven segmentLED-display - supply voltage: 24 VDC ±10 % - temperature sensor:: Pt 100 - description: thermotronic controler for surface mounting on devices as Nivotemp 62-2-C6F, with 6 output switches for temperature and 3 output switches for level control |
part-no.:1410499
|
Bühler
|
13
|
Temp cold gas gen
|
1 set included:
-01 pc Connection Head, weather-proof CH103 series Model CH103P3W0 -01 pc sensor, resistant thermometer, triplex Probe Type, Tip-sensitive S102495 series PDPDPD60Z144 -01 pc accessories: process and conduit connection 1/2" NPT |
|
MINCO
|
14
|
Control Unit
|
- Control Unit (Model: SDS 2000 series )
- Power: 220VAC - Water/steam interface: 0.6- 1.6 - Number of electrode: 2 (2 channel). - Electrode cable lenght: 10m. - Local displays:level indication steam= Red Led/ Water= Green Led. - Enclosure: Poly- carbonate case.4 Point wall mount, - Size 360(H) X 320(W) X 160(D) - IP65.NEMA4.Net Weight 4.5Kg. |
Part No: SDS 2000
|
SEOJIN INSTECH
|
15
|
Speed and direction monitor
|
- Model:D124.1S2U2M
- Specifications: 1.Design - Series „D“:snap-on track enclosure for DIN 50022 rail 35 mm, - Dimensions:..length 100 mm, width 75 mm, height 111 mm. 2.Installation Conditions: - Ambient temperature in operation; Standard model:0°C...+50°C - Model with suffix M (extended range):0°C...+65°C - Ambient temperature in storage :-40°C....+85°C - Electrical insulation grade : I Voltage grade :I - Protection grade:IP20 for terminals 3.Power Supply - Supply voltage version U2M:85..265Vac/dc - Consumption :5 W resp. 5 VA 4.Signal input - Matching speed/direction sensors :series A5S3..to other sources:response level on/off >7 volts/<4 volts - Input impedance 100 kohms - Sensor supply approx. 12 volts/max. 60 ma; Speed measurement sequence ..30 msec .. 10 sec (programmable) 5.Accuracy: + 0.005 % of measurement + 1 in LSD 6.Analog output - Isolated and programmable:0/4.../20ma; Resolution:12 bit - Max. load:500 ohms; Linearity error:0.1 % 7.Relay outputs:2, each SPDT - Breaking capacity:voltage min 10 mv, max 250 v AC/DC; Current min. 10 ua, max 2 amp AC, 1 amp DC - Power rating max 100 W, 250 VA into ohmic load only; Inductive load must be equipped with spark extinguisher 8.Display:5 digits LED red, with adjustable decimal point, programmable |
|
Rraun
|
16
|
Oxygen Analyser
|
Type: DIGOX 5 K
Measuring range: 0,1 ... 20000 μg/l O2 Measuring method: Potentiostatic 3-electrode measuring system Recorder output: via current loop: 0...20mA/ 4...20mA, freely selectable 2. Flow 0-20l/h |
|
Dr. Thiedig, Germany
|
17
|
Digox 5 K service set (stationary)
|
|
Item No: DG 55.30.00
|
Dr. Thiedig, Germany
|
18
|
Replacement diaphragm
|
|
Item No: DG 50.09.00
|
Dr. Thiedig, Germany
|
19
|
Filter tube for coarse filter
|
|
Item No: OF 86.00.04
|
Dr. Thiedig, Germany
|
20
|
Fine-mesh filter inset
|
|
Item No: ZZ 13.00.42
|
Dr. Thiedig, Germany
|
21
|
Monitor Module
|
Model no: FMM-101 Monitor Module
-Nominal Operating Voltage: 15-32 VDC - Average Operating Current: 375µA maximum - EOL resistance: 47K Ohms - Maximum IDC wiring resistance: 1,500 Ohms - Temperature Range: 32˚ to 120˚ F (0˚ to 49˚ C) - Humidity: 10 to 93% noncondensing - Dimensions: 1.3″ H x 2.75″ W x 0.5″ D - Wire length: 6″ minimum |
|
Notifier
|
22
|
Relay Control Module
|
- MOdel no: FRM-1 Relay Control Module
- Normal Operating Voltage: 15 to 32 VDC - Maximum Current Draw: 6.5 mA (LED on) - Average Operating Current: 270µA (LED flashing) EOL Resistance: Not used - Temperature Range: 32˚F to 120˚F (0˚C to 49˚C) - Humidity: 10% to 93% Noncondensing - Dimensions: 41/ 2″ H x 4″ W x 11/4″ D (Mounts to a 4″ square by 21/8″ deep box.) - I252Accessories: SMB500 Electrical Box; CB500 Barrier |
|
Notifier
|
25
|
Smoke Detector
|
- Model no: FSP-851
- Operating Temperature: FSP-851, 0°C to 49°C - UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. 1 set include: - Relative Humidity: 10%-93% noncondensing. - Smoke detector (1pc): - Voltage Range: 15-32 volts DC peak. - Standby Current (max. avg.): 300μA @ 24VDC (one communication every five seconds with LED enabled). - LED Current (max.): 6.5mA @ 24VDC (‘ON’). |
|
Notifier
|
27
|
Power Supply
|
- Model : AMPS-24/E
- Addressable by NFS-3030/NFS2-3030 FACP. - Primary (AC) power: AMPS24E: 220-240 VAC 50/60 Hz input, 2.5 A maximum. - Agency Listings and Approvals: + UL: S635 + ULC: CS118 + City of Chicago + City of Denver + MEA: 345-02-E + CSFM: 7165-0028:224 + FM: Approved + FDNY: #6026 |
|
Notifier
|
23
|
Manual Call Point red
|
- PROTECTION : Dust-tight & Weatherproof
- INGRESS PROTECTION: IP66 & IP67 - TERMINALS: 6 x 4.0mm2 - SWITCH RATINGS: + DC: 0 - 30V 3A resistive or inductive; 30V - 50V 1A resistive or inductive; + AC: 0 - 250V 3A resistive or inductive; - RESISTOR VALUES: 270R Minimum; - Material: UV resistant glass reinforced polyester - Label Type: Glass Label Fire Break Glass 'Press Here - Feature: Double changeover - Entries:2x20mm (bottom) - For blanking plugs add “P’ to code. e.g. BP, 2 x 20mm bottom entries with one blanking plug. - Colour: Natural Red |
Ordering No: BG3W1TBPR
|
MEDC
|
24
|
Alarm Bell
|
-SSM Series:SSM24-6
- Voltage:Regulated 24 VDC - Operating Voltage Limit:16 - 33 VDC - Maximum Current: DC - 31.1mA/FWR - 53.5mA - Operating Temperature: –31° to 150°F (–35° to +66°C) - UL Reverberant Room Sound Output per UL 464 (dBA):82 |
|
System Sensor
|
26
|
Outdoor Wall Strobe
|
-Standard operating temperature: 32°F to 120°F (0°C to 49°C).
- Humidity range: 10% to 93% non-condensing (indoor products). - Operating voltage range: 16 V to 33 V (24 V nominal) - 2-wire horn/strobe, standard cd, red, outdoor. |
Model :P2RK
|
FIRE·LITE®ALARM
|
28
|
Single Channel Control Card
|
- Analogue Output: 4-20 mA;
- LEDs: A1, A2, A3 gas alarms.Fault and Inhibit. - Push-Button: Alarm Reset/Card Select; - Alarm Setting Point Resolution: In 1% fsd steps; - Display/Alarm Point: + Linearity: ±1% fsd. + Repeatability: ±1% fsd. - Remote Facilities: Inhibit/Alarm Reset; - Remote Inhibit / Reset Inputs: + Active For Inputs: More than 2V. + Maximum Input Voltage: 32V. + Maximum Input Current: 5mA. - Power Consumption: + Catalytic: 3.75W (typical); (Includes Catalytic Sensor). + 4 - 20mA: 3.25W (typical). - DC Supply: 18V to 32V dc. - Electronic Drift: Less than ±2% / 6 months |
Part Number: 05701-A-0301
|
Honeywell
|
29
|
007 Series Switchbox
|
- Type: 007AA01212Nil
- IP 67 - Namur shaft -standard - 2x1/2" NPT - Honeywell V15 SPDT 250VDC 0.25A/250VAC 10A mechanical |
|
KENWOOD VALVE CONTROLS
|
30
|
007 Series Switchbox
|
- Type: 007AA01212Nil
- IP 67 - Namur shaft -standard - 2x1/2" NPT - Honeywell V15 SPDT 250VDC 0.25A/250VAC 10A mechanical |
|
KENWOOD VALVE CONTROLS
|
31
|
Heavy Duty Platform Scale - MS
|
- Model: CTG 2T4L
- Capacity: 2 Ton - Readability: 500g - Pan size: 1200x1200 mm - Display: LCD display - Power supply: 230+10%Vac; 50Hz |
|
Citizen
|
32
|
Air duct temperature
|
- Thermasgard KTF 1 PT100 2L
- Connection type: 2 -Wire connection - Measuring range : -30...+150 Deg C - Ub max :42VAC/60VDC |
|
S+S Regeltechnik GmbH
|
33
|
Air duct temperature
|
-Thermasgard KTF 1 PT100 2L
- Connection type: 2 -Wire connection - Measuring range : -30...+150 Deg C - Ub max :42VAC/60VDC |
|
S+S Regeltechnik GmbH
|