Đại lý BALLUFF Việt Nam, BALLUFF Vietnam, BKS-S33M-00, BTL5-E17-M0075-B-NEX-S32, 37512140, 37512141, 37512192, MT-EOL 2K I 30 NL=1100, KARLSTEIN GERMANY, 2866776, PHOENIX CONTACT, SDS 2000,  KTF 1 PT100 2L, S+S Regeltechnik GmbH 

No
Name
Description
Part number
Manufacturer
1
Electrical switch
T y p e: 1 6 9 0
Contact: SPDT, bistable
Contact material: rhodium
Voltage: 230 V AC/DC
Power switching: 40 W / 60 VA
Enclosure rating: IP 67 (IEC 529)
Connection: PVC-cable, length 3 m (standard)
Housing material: Plastic (PBT black)
Part-No. :641.6502.380.LI
Intra-automation
2
Micropulse linear transducer
- Type:BTL5-E17-M0075-B-NEX-S32
-Current output: E17 =20...4 mA, falling
-Standard nominal stroke: 0075
-Housing: B M18×1.5
-Connection type: S32 with connector
 
BALLUFF
3
Connector
- Type: BKS-S33M-00
- Electrical connection:
+ Cable diameter D :8mm
+ Contact shield: Shield ring
+ Number of pins: 8
+ System; Can be fabricated
- Electrical data:
+ Rated current (40 °C): 5.0 A
-  Environmental conditions:
+Ambient temperature: -40…95 °C
+Protection type IEC 60529: IP67
- Material:
+ Material contact carrier : PBT
+ Material contacts :Bronze
+ Material cover nut : Brass
+ Material grip: Die-cast zinc
- Mechanical data:
+Connection cross-section: 0.75 mm²
+Type of wire mounting :Solder connections
 
BALLUFF
10
Micropulse linear transducer
- Type:BTL5-E17-M0075-B-NEX-S32
-Current output: E17 =20...4 mA, falling
-Standard nominal stroke: 0075
-Housing: B M18×1.5
-Connection type: S32 with connector
 
BALLUFF
11
Connector
- Type: BKS-S33M-00
- Electrical connection:
+ Cable diameter D :8mm
+ Contact shield: Shield ring
+ Number of pins: 8
+ System; Can be fabricated
- Electrical data:
+ Rated current (40 °C): 5.0 A
-  Environmental conditions:
+Ambient temperature: -40…95 °C
+Protection type IEC 60529: IP67
- Material:
+ Material contact carrier : PBT
+ Material contacts :Bronze
+ Material cover nut : Brass
+ Material grip: Die-cast zinc
- Mechanical data:
+Connection cross-section: 0.75 mm²
+Type of wire mounting :Solder connections
 
BALLUFF
4
Thermocouple
- MODEL:37512140
- Type: MT- EOL 2K I 30 NL=3100
-  Nicr-Ni dia 3 x 3000 38Z1-01955
- TEMP: 0..+10000C
 
KARLSTEIN GERMANY
5
Thermocouple
- MODEL:37512141
- Type:MT- EOL 2K I 30 NL=2100
-TEMP: 0..+10000C
- Nicr-Ni dia 3 x 2000 38Z1-01955
 
KARLSTEIN GERMANY
6
Thermocouple
- MODEL:37512192
- Type:MT-EOL 2K I 30 NL=3300
-TEMP: 0..+10000C
-  Nicr-Ni dia 3 x 3200
-  Nicr-Ni dia 3 x 1000
 
KARLSTEIN GERMANY
7
Thermocouple
- Type:MT-EOL 2K I 30 NL=1100
-TEMP: 0..+1000 deg C
 
KARLSTEIN GERMANY
8
Power supply
-Input data:
+ Nominal input voltage:100 V AC ... 240 V AC
+ AC input voltage range: 85 V AC ... 264 V AC
+ DC input voltage range: 90 V DC ... 350 V DC
+Short-term input voltage:300 V AC
+ AC frequency range:45 Hz ... 65 Hz
- Output data:
+ Nominal output voltage:24 V DC ±1%
+ Setting range of the output voltage:18 V DC ... 29.5 V DC (> 24 V constant capacity)
+Output current: 20 A (-25°C ... 60°C, UOUT = 24 V DC)
Order No.: 2866776
PHOENIX CONTACT
9
Condensate Drainage
Model: 20 FM
Voltage: 230Vac
Pressure:0.8-16bar
Connections Inlet:1x G 1/2
Connections outlet:1x G 1/4
 
BEKOMAT
12
Thermotronic 61 Electronic temperature sensor
-  type: Thermotronic 61-00V004
- range of temperature display:: from -20 to +120 °C
- range of alarm indication:0 to +99 °C
- display: : three digit seven segmentLED-display
- supply voltage: 24 VDC ±10 %
- temperature sensor:: Pt 100
- description: thermotronic controler for surface mounting on devices as Nivotemp 62-2-C6F, with 6 output switches for temperature
and 3 output switches for level control
part-no.:1410499
Bühler
13
Temp cold gas gen
1 set included:
-01 pc Connection Head, weather-proof CH103 series Model CH103P3W0
-01 pc sensor, resistant thermometer, triplex Probe Type, Tip-sensitive S102495 series PDPDPD60Z144
-01 pc accessories: process and conduit connection 1/2" NPT
 
MINCO
14
Control Unit
- Control Unit (Model: SDS 2000 series )
- Power: 220VAC
- Water/steam interface: 0.6- 1.6
- Number of electrode: 2 (2 channel).
- Electrode cable lenght: 10m.
- Local displays:level indication steam= Red Led/ Water= Green Led.
- Enclosure: Poly- carbonate case.4 Point wall mount,
 - Size 360(H) X 320(W) X 160(D)
  - IP65.NEMA4.Net Weight 4.5Kg.
Part No: SDS 2000
SEOJIN INSTECH
15
Speed and direction monitor
- Model:D124.1S2U2M
- Specifications:
1.Design
- Series „D“:snap-on track enclosure for DIN 50022 rail 35 mm,
- Dimensions:..length 100 mm, width 75 mm, height 111 mm.
2.Installation Conditions:
- Ambient temperature in operation; Standard model:0°C...+50°C
- Model with suffix M (extended range):0°C...+65°C
- Ambient temperature in storage :-40°C....+85°C
- Electrical insulation grade : I
Voltage grade :I
- Protection grade:IP20 for terminals
3.Power Supply
- Supply voltage version U2M:85..265Vac/dc
- Consumption :5 W resp. 5 VA
4.Signal input
- Matching speed/direction sensors :series A5S3..to other sources:response level on/off >7 volts/<4 volts
- Input impedance 100 kohms
- Sensor supply approx. 12 volts/max. 60 ma; Speed measurement sequence ..30 msec .. 10 sec (programmable)
5.Accuracy: + 0.005 % of measurement + 1 in LSD
6.Analog output
- Isolated and programmable:0/4.../20ma; Resolution:12 bit
- Max. load:500 ohms; Linearity error:0.1 %
7.Relay outputs:2, each SPDT
- Breaking capacity:voltage min 10 mv, max 250 v AC/DC; Current min. 10 ua, max 2 amp AC, 1 amp DC
- Power rating max 100 W, 250 VA into ohmic load only; Inductive load must be equipped with spark extinguisher
8.Display:5 digits LED red, with adjustable decimal point, programmable
 
Rraun
16
Oxygen Analyser
Type: DIGOX 5 K
Measuring range: 0,1 ... 20000 μg/l O2
Measuring method: Potentiostatic 3-electrode measuring system
Recorder output: via current loop: 0...20mA/ 4...20mA, freely selectable
2. Flow 0-20l/h
 
Dr. Thiedig, Germany
17
Digox 5 K service set (stationary)
 
Item No: DG 55.30.00
Dr. Thiedig, Germany
18
Replacement diaphragm
 
Item No: DG 50.09.00
Dr. Thiedig, Germany
19
Filter tube for coarse filter
 
Item No: OF 86.00.04
Dr. Thiedig, Germany
20
Fine-mesh filter inset
 
Item No: ZZ 13.00.42
Dr. Thiedig, Germany
21
Monitor Module
Model no: FMM-101 Monitor Module
-Nominal Operating Voltage: 15-32 VDC
- Average Operating Current: 375µA maximum
- EOL resistance: 47K Ohms
- Maximum IDC wiring resistance: 1,500 Ohms
- Temperature Range: 32˚ to 120˚ F (0˚ to 49˚ C)
- Humidity: 10 to 93% noncondensing
- Dimensions: 1.3″ H x 2.75″ W x 0.5″ D
- Wire length: 6″ minimum
 
Notifier
22
Relay Control Module
- MOdel no: FRM-1 Relay Control Module
- Normal Operating Voltage: 15 to 32 VDC
- Maximum Current Draw: 6.5 mA (LED on)
- Average Operating Current: 270µA (LED flashing)
EOL Resistance: Not used
- Temperature Range: 32˚F to 120˚F (0˚C to 49˚C)
- Humidity: 10% to 93% Noncondensing
- Dimensions: 41/
2″ H x 4″ W x 11/4″ D (Mounts to a 4″ square by 21/8″ deep box.)
- I252Accessories: SMB500 Electrical Box; CB500 Barrier
 
Notifier
25
Smoke Detector
- Model no: FSP-851
- Operating Temperature: FSP-851, 0°C to 49°C
- UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. 1 set include:
- Relative Humidity: 10%-93% noncondensing.
- Smoke detector (1pc):
- Voltage Range: 15-32 volts DC peak.
- Standby Current (max. avg.): 300μA @ 24VDC (one communication every five seconds with LED enabled).
- LED Current (max.): 6.5mA @ 24VDC (‘ON’).
 
Notifier
27
Power Supply
- Model : AMPS-24/E
- Addressable by NFS-3030/NFS2-3030 FACP.
-  Primary (AC) power: AMPS24E: 220-240 VAC 50/60 Hz input, 2.5 A maximum.
- Agency Listings and Approvals:
+ UL: S635
+ ULC: CS118
+ City of Chicago
+ City of Denver
+ MEA: 345-02-E
+ CSFM: 7165-0028:224
+ FM: Approved
+ FDNY: #6026
 
Notifier
23
Manual Call Point red
- PROTECTION : Dust-tight & Weatherproof
- INGRESS PROTECTION: IP66 & IP67
- TERMINALS: 6 x 4.0mm2
- SWITCH RATINGS:
     + DC: 0 - 30V 3A resistive or inductive; 30V - 50V 1A resistive or inductive;
     + AC: 0 - 250V 3A resistive or inductive;
- RESISTOR VALUES: 270R Minimum;
- Material: UV resistant glass reinforced polyester
- Label Type: Glass Label Fire Break Glass 'Press Here
- Feature: Double changeover
- Entries:2x20mm (bottom)
- For blanking plugs add “P’ to code. e.g. BP, 2 x 20mm
bottom entries with one blanking plug.
- Colour: Natural Red
Ordering No: BG3W1TBPR
MEDC
24
Alarm  Bell
-SSM Series:SSM24-6
- Voltage:Regulated 24 VDC
- Operating Voltage Limit:16 - 33 VDC
- Maximum Current: DC - 31.1mA/FWR - 53.5mA
- Operating Temperature: –31° to 150°F (–35° to +66°C)
- UL Reverberant Room Sound Output per UL 464 (dBA):82
 
System Sensor
26
Outdoor Wall Strobe
-Standard operating temperature: 32°F to 120°F (0°C to 49°C).
- Humidity range: 10% to 93% non-condensing (indoor
products).
- Operating voltage range: 16 V to 33 V (24 V nominal)
- 2-wire horn/strobe, standard cd, red, outdoor.
Model :P2RK
FIRE·LITE®ALARM
28
Single Channel Control Card
- Analogue Output: 4-20 mA;
- LEDs: A1, A2, A3 gas alarms.Fault and Inhibit.
- Push-Button: Alarm Reset/Card Select;
- Alarm Setting Point Resolution: In 1% fsd steps;
- Display/Alarm Point:
     + Linearity: ±1% fsd.
     + Repeatability: ±1% fsd.
- Remote Facilities: Inhibit/Alarm Reset;
- Remote Inhibit / Reset Inputs:
     + Active For Inputs: More than 2V.
     + Maximum Input Voltage: 32V.
     + Maximum Input Current: 5mA.
- Power Consumption:
    + Catalytic: 3.75W (typical); (Includes Catalytic Sensor).
    + 4 - 20mA: 3.25W (typical).
- DC Supply: 18V to 32V dc.
- Electronic Drift: Less than ±2% / 6 months
Part Number: 05701-A-0301
Honeywell
29
007 Series Switchbox
- Type: 007AA01212Nil
- IP 67
- Namur shaft -standard
- 2x1/2" NPT
- Honeywell V15 SPDT 250VDC 0.25A/250VAC 10A mechanical
 
KENWOOD VALVE CONTROLS
30
007 Series Switchbox
- Type: 007AA01212Nil
- IP 67
- Namur shaft -standard
- 2x1/2" NPT
- Honeywell V15 SPDT 250VDC 0.25A/250VAC 10A mechanical
 
KENWOOD VALVE CONTROLS
31
Heavy Duty Platform Scale - MS
- Model: CTG 2T4L
- Capacity: 2 Ton
- Readability: 500g
- Pan size: 1200x1200 mm
- Display: LCD display
- Power supply: 230+10%Vac; 50Hz
 
Citizen
32
Air duct temperature
- Thermasgard KTF 1 PT100 2L
- Connection type: 2 -Wire connection
- Measuring range : -30...+150 Deg C
- Ub max :42VAC/60VDC
 
S+S Regeltechnik GmbH
33
Air duct temperature
-Thermasgard KTF 1 PT100 2L
- Connection type: 2 -Wire connection
- Measuring range : -30...+150 Deg C
- Ub max :42VAC/60VDC
 
S+S Regeltechnik GmbH